GLAST/LAT > DAQ and FSW > FSW > Doxygen Index > XFC_DB / V2-0-0
Constituent: mfc_db_eff_taper_off_axis     Tag: linux-gcc
This graph shows which files directly or indirectly include this file:
Defines | |
#define | DEFAULT__Cal_Elo 5 Mev |
The lower energy threshold, expressed in MEV, used to determine if the energy deposited is in the 1 MIP range. With a MIP in the CAL being ~12 Mev, this number is typically set to ~5 Mev. This is the default value. | |
#define | DEFAULT__Cal_Ehi 25 Mev |
The upper energy threshold, expressed in MEV, used to determine if the energy deposited is in the 1 MIP range. With a MIP in the CAL being ~12 Mev, this number is typically set to ~25 Mev. This is the default value. | |
#define | DEFAULT__Cal_Nlayers 3 Layers |
The number of layers to check for minimum ionizing. The test for failure is greater than this value. Typical value is 3. This is the default value. | |
#define | DEFAULT__Tkr_Placeholder 0 |
Placeholder, default value. | |
#define | MFC_DB_DATA_PRMS |
Template for the Minimum Ionizing Particle Filter Parameters. | |
#define | DEFAULT__Active_Passes_Vetoes 0x7fffc000 |
The list of vetoes to use. | |
#define | MFC_DB_DATA_SAMPLER |
Template for the Minimum Ionizing Particle Filter Sampling Parameters. | |
#define | MFC_DB_DATA(_name) |
Template for the Minimum Ionizing Particle Filter Sampling Parameters. |
CVS $Id: MFC_DB_macros.h,v 1.2 2007/06/26 18:52:59 jgt Exp $
|
Value: static const MFC_DB_schema MFC_DB_ ## _name = \ { \ MFC_DB_DATA_SAMPLER, \ MFC_DB_DATA_PRMS \ };
|
|
Value: { \ { \ Cal_Elo, \ Cal_Ehi, \ Cal_Nlayers, \ }, \ \ { \ Tkr_Placeholder \ } \ }
|